Notice: Trying to get property 'post_type' of non-object in /var/www/testnordic.com/en.testnordic.com/wp-includes/class-wp-query.php on line 4222
HVA60 AC Hipot Tester | VLF Hipot Tester | Testnordic.com
Deprecated: Unparenthesized `a ? b : c ? d : e` is deprecated. Use either `(a ? b : c) ? d : e` or `a ? b : (c ? d : e)` in /var/www/testnordic.com/en.testnordic.com/wp-content/plugins/responsive-menu-pro/vendor/twig/twig/lib/Twig/Node.php on line 42

HVA60

SKU: N/A

The HVA60 AC hipot by b2hv is a portable 0.1 Hz VLF cable test system for the testing of medium voltage cables.

Description

HVA60-DHV1210-Rev04At only 57 kg this compact AC hipot is truly quite remarkable and as such is ideal for mobile use. The powerful output is capable of driving capacitive loads of up to 10 μF.  At maximum output voltage cables with a lengthof up to 15 km can be tested.

Possible output voltages:

  • Sinusoidal: 0 – 62 kV peak, 0 – 44 kV eff
  • DC: ± 0 – 60 kV
  • Squarewave: 60 kV

The HVA60 AC hipot offers various operating modes. Cable testing, cable sheath / jacket testing, sheath fault location, cable fault conditioning (burning), vacuum bottle test.

The following features make the HVA60 AC hipot the outstanding cable test system of its class:

  • Predefined standard-compliant cable test sequences
  • Symmetrical sine wave at high voltage
  • RMS measurement of output voltage and current
  • Measurement of capacitive and resistive load
  • Automatic load dependent frequency selection (0.01 Hz – 0.1 Hz)
  • Display of current test time
  • Integrated real-time scope function
  • Self-explanatory, multilingual software
  • Automatic measurement reporting
  • Report storage via RS232 or USB optional
  • PC software (b2 ControlCenter) for data analysis and storage
  • Flashover detection and ultra fast switch off
  • Flashover voltage measurement
  • Time optimized burning mode
  • No regular maintenance required

The fully comprehensive safety features guarantee protection of operator and test instrument.

  • Short circuit protected output
  • 12 kV feedback protection
  • Signal lamps for active / inactive high voltage
  • Status display of safety functions
  • Dual Discharge Device DDD®, elektronische und mechanische Entladeeinrichtung (integriert)
  • Main switch with key-lock
  • Emergency-off button on front panel

A SINGLE device for NUMEROUS applications:

  • Cables: XLPE , PE, EPR, PILC, etc.
  • Capacitors
  • Switchgear
  • Transformers
  • Rotating machines (IEEE 433)
  • Isolators
  • Bushings

 

Brochure