Notice: Trying to get property 'post_type' of non-object in /var/www/testnordic.com/en.testnordic.com/wp-includes/class-wp-query.php on line 4222
MIC-5050 | Insulation Resistance Measurement | Testnordic.com
Deprecated: Unparenthesized `a ? b : c ? d : e` is deprecated. Use either `(a ? b : c) ? d : e` or `a ? b : (c ? d : e)` in /var/www/testnordic.com/en.testnordic.com/wp-content/plugins/responsive-menu-pro/vendor/twig/twig/lib/Twig/Node.php on line 42

MIC-5050

It is especially recommended for measurements in areas with very high electromagnetic disturbances

Description

MIC-5050 used for Insulation resistance measurement: up to 20 TΩ,

  • Measurement voltage any in the range of: 50…5000 V (50…1000 V at 10 V and 1…5 kV at 25 V),
  • Continuous indication of measured insulation resistance or leakage current,
  • Automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement,
  • Acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics,
  • Adjustable measuring time to 99’59’’,
  • Metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s,
  • Polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement,
  • Indication of actual test voltage during measurement,
  • 1.2 mA, 3 mA and 6 mA+/-15% test current,
  • Insulation resistance measurement using two- or three-wire method,
  • Measurements with test leads up to 20 m…
  • Protection against measuring live objects,
  • Automatic measurement of multiple core cables with the additional AutoISO-5000 adapter
  • Measurement of capacitance during the measurement of RISO.
  • Measurement of temperature (with additional probe – WASONT1),
  • Step voltage insulation resistance measurement (SV),
  • Dielectric Discharge calculation (DD),
  • Location of damage (burnout),

Digital filters function for measurements in high noise environment.
Measurement of leakage current during insulation resistance testing.
DC and AC voltage measurement in the range of  0…750 V.
Drawing graphs on the display during measurement.
Innovative  memory  with possibility of description of:  measurement points,  facilities,  names  of  customers.
Operating with mini Bluetooth keyboard (option).
Graphic LCD 5,6’’ backlit.
Keyboard backlit.
Power supply from main power line or battery packs.
Built-in fast charger.
The instruments meet the requirements of the EN 61557 standard.

 

Brochure