Description
Small Handheld TDR-410
- Location damaged power cables.
- Fault location copper telecom cables.
- Coaxial cable fault location.
- Fault location wiring infrastructure.
- Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
- Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.
Features:
Automatic or manual mode:
- the automatic fault location (AFL),
- mode with manual range selection and sensitivity,
- single measurement triggered manually or scanning continuous,
- 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
- maximum length of cable up to 4000 m one end of the cable,
- “Dead zone” measure limited to 0.5 m,
- 2.5 “LCD screen with backlight,
- scan automatically or manually trigger,
- sensitivity set manually or automatically adjusted,
- adjustable impedance matching,
- propagation coefficient adjustment 1% to 99%,
- waterproof and resistant to mechanical housing.
- small size and weight.
- economical power system – 30 hours of continuously scan on one battery set.
Technical data:
- Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
- Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
- Range Selection: Manual range control / Auto range.
- Accuracy: 1% of selected range*.
- Resolution: Approx 1% of range.
- Minimum cable lenght: 4m (14ft).
- Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
- Velocity Factor: Adjustable from 1% to 99%.
- Output Pulse: 5 volts peak to peak into open circuit.
- Output Impedance: Selectable 25, 50, 75 & 100 Ω.
- Output Pulse: Width 3 ns to 3 µs, Automatic with range.
- Scan Rate: 2 scans/second or scan held, pre set for each range scale.
- Tone Generator: 810 – 1100Hz.
- Battery Life: 30 hours continuous scanning.
- Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
- Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
- Back Lit Display: 128 x 64 pixel.
- Voltage Protection: 250 volts AC.
- Operating Temp: -10º / 50ºC.
- Storage Temp: -20º +70° C.
- Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
- Weight: 350 g (12oz).
- Safety: IEC 61010-1, EN 60950.
- EMC: BS/EN 61326-1.
- Water/Dust Proof: IP54.
Accessories:
- 0,6 m double-wire lead: WAPRZ0X6DZBB
- red crocodile clip: WAKRORE20K02
- Krokodylek czarny: WAKROBL20K01
- cover M-2: WAFUTM2